Skip to content
Dental TI

Flagship · True wireless direct conversion

The radiograph, captured. Not synthesized.

DC-Air™ is dentistry's first and only Bluetooth® wireless, direct-conversion intraoral sensor. X-ray photons convert straight to signal — no scintillator, no sharpening filters, and no cable out of your patient's mouth.

  • Best Image Quality — Clinicians Report® 2026 Buying Guide
  • Top Award Winner — Dental Advisor 2024
  • Best Product — Dental Product Shopper

Installation, integration, training & expert support included — since 2003.View the brochure (PDF)

Unfiltered DC-Air posterior bitewing radiograph at high magnification, enamel and dentin detailDC-Air™ capture · 26 µm px1,249,920 px · 12-bit · IP67
DC-Air wireless sensor floating above its charging dock
5.0 · 132 Google Reviews

Serving dentistry since 2003

Installation, training & expert support included

Independently evaluated

Don’t take our word for it. Take theirs.

Clinicians Report® 2026 Buying Guide

Best Image Quality

Independent evaluation by the CR Foundation

Dental Advisor 2024 — Top Award Winner

Top Award Winner — Dental Advisor 2024

Annual clinical product awards

Dental Product Shopper — Best Product

Best Product — Dental Product Shopper

Clinician evaluation score 4.6 / 5


Three problems every operatory knows. One sensor built to remove them.

No more cables

The cable is the number-one failure point on conventional sensors — so DC-Air eliminates it. Bluetooth® Low Energy carries every capture about 3 m to your PC, and with nothing dragging the sensor out of position, FTG reports up to 40% fewer retakes.

No more fragile layers

No scintillator, no fiber-optic plate — the delicate layers that make conventional scintillator sensors expensive to break. Just one single-crystal silicon detector in an IP67-sealed body that shrugs off wipe-downs.

No more synthesized detail

Conventional sensors convert X-rays to light, light to signal — then sharpen the blur away in software. DC-Air converts photons directly to charge and applies brightness and contrast only. Never sharpening.


The evidence, at native resolution

Read the evidence yourself.

22 clinical DC-Air captures, straight off the sensor — brightness and contrast only, never sharpened. Zoom to the pixels. Then window-level them yourself.

Control or command scroll, or pinch, to zoom; drag to pan when zoomed in. At the default fit view the image is fixed. Keyboard: plus and minus keys zoom, arrow keys pan, Home resets the view, left and right bracket keys switch cases. The brightness and contrast button opens a two-axis pad; inside it, arrow keys adjust and Home returns to neutral.

Posterior bitewing

Bitewings

Periapicals

Endodontic

Implants


See the difference direct conversion makes

The same exposure, two technologies. Drag the divider to compare a conventional scintillator sensor with DC-Air's direct-conversion image.

The same radiograph captured with the DC-Air direct-conversion sensor, showing greater clarity and detail
Radiograph captured with a conventional scintillator-based sensor
Conventional scintillator sensorDC-Air™ direct conversion

Single-crystal direct conversion

Nothing between the photon and the diagnosis

Conventional scintillator sensors never see the X-ray at all. A scintillator layer converts it to visible light, the light spreads sideways through a fiber-optic plate, and only then does silicon record it — blurred by every step, then patched up with manufacturer sharpening filters.

DC-Air's single-crystal direct-conversion silicon CMOS converts each photon directly to charge at the exact point where it lands. No scintillator. No fiber-optic plate. No sharpening — captures get brightness and contrast adjustment only. Captured, not synthesized.

MTF — modulation transfer function
5 lp/mm
>70%
10 lp/mm
>40%

In FTG’s published MTF testing. MTF measures how much of the original contrast survives at each level of fine detail — higher means sharper, straight off the detector.

Exploded view of the DC-Air sensor's internals: sealed housing, battery, electronics, and the single-crystal direct-conversion silicon detector

360° positioning

Position it any way the anatomy demands

With no cable dictating orientation, DC-Air captures in distal or mesial orientation — a full 360° of placement freedom. Zero Profile® holders clip directly to the back of the sensor and add no bulk, so nothing extra goes in the mouth.

Drag the sensor to look it over from every side — or step through the views with the arrow keys.

DC-Air wireless sensor, studio view

DC-Air™ sensor · 6 studio views


Zero Profile® holders

Color-coded for every workflow

Every Starter Kit includes the complete Zero Profile® holder kit. Refill 3-packs are available in every color — grab the one your procedure calls for.

Zero Profile bitewing holder 3-pack

Bitewing

Red · refill 3-packs available

Zero Profile anterior holder 3-pack

Anterior

Blue · refill 3-packs available

Zero Profile posterior holder 3-pack

Posterior

Yellow · refill 3-packs available

Zero Profile endodontic holder 3-pack

Endodontic

Clear · refill 3-packs available

The complete Zero Profile holder set with positioning rings
Zero Profile positioning ring 3-pack

The complete set

All four holder types plus positioning rings — included with every DC-Air Starter Kit, with 3-pack refills available whenever you need them.


DC-Air™ specifications

DC-Air™ Wireless X-Ray Sensor specifications
Sensor sizeSize 2
Active area35.1 × 24.7 mm
Pixel pitch26 µm
Resolution1,249,920 pixels · 12-bit
MTF>70% @ 5 lp/mm · >40% @ 10 lp/mm — in FTG’s published MTF testing
DetectorSingle-crystal direct-conversion silicon CMOS — no scintillator, no fiber-optic plate
ConnectivityBluetooth® Low Energy · ~3 m range · auto-triggers on exposure · 4 MB onboard buffer
Exposure range0.08–1 s @ 65–70 kV, 2–10 mA
Battery150+ radiographs per charge · recharges in under 1 minute on the dock · 19 mAh Li-Ion
DurabilityIP67-sealed body
Positioning360° — distal or mesial orientation with Zero Profile® holders
In the kitSensor · docking station · USB-C cable · Zero Profile® complete holder kit · TWAIN license (one network, unlimited PCs) · 2-year warranty

DC-Air™ is manufactured byFreedom Technologies Group ↗


DC-Air™ Starter Kit

Go wireless — call for current pricing

Everything a practice needs to go wireless: DC-Air™ sensor, charging dock, holders, and integration with your imaging software.

Everything in the DC-Air Starter Kit laid out: sensor, docking station, cable, and Zero Profile holders

What the Starter Kit includes

  • DC-Air™ wireless sensorIncluded
  • Docking stationIncluded
  • Zero Profile® complete holder kit — refill 3-packs availableIncluded
  • USB-C cableIncluded
  • TWAIN license — one network, unlimited PCsIncluded
  • 2-year manufacturer warrantyIncluded
  • Professional installation — Dental TI teamIncluded
  • Imaging software integrationIncluded
  • Remote team training — on-site availableIncluded
  • Expert support — remote and on-siteIncluded
DC-Air™ Starter KitCall for current pricing

Call 800-672-5733 for current pricing, promotions, and bulk pricing.

Financing available — pay over time with Affirm

Excluding sales tax · Shipping & return policy

Rather see it first?

Tell us where to send DC-Air pricing, or book a live demo and we'll put one in your hands.


Compatibility

Works with the software you already run

Native integration with the major imaging platforms, and a TWAIN license covering one network with unlimited PCs for everything else.

  • Open Dental
  • Dentrix
  • Dentrix Ascend
  • Eaglesoft
  • XDR
  • DEXIS
  • Apteryx
  • Curve
  • + 9 more via TWAIN

Want one imaging suite across every operatory?Pair DC-Air with CADI Advanced Imaging →


DC-Air™ questions, answered

Does DC-Air integrate with my existing imaging software?

Yes. DC-Air includes a TWAIN license covering one network with unlimited PCs, plus native integration with Open Dental, Dentrix, Dentrix Ascend, Eaglesoft, XDR, DEXIS, Apteryx, Curve, and 9+ more. Dental TI handles the integration as part of every installation — if you’re unsure about yours, ask during your demo and we’ll confirm before you buy.

How long does the battery last?

DC-Air captures 150+ radiographs per charge — comfortably more than a full clinical day for most operatories — and recharges in under 1 minute on its docking station, so a between-patient top-up is all it ever needs.

How reliable is a wireless sensor during an exposure?

DC-Air connects over Bluetooth® Low Energy with roughly 3 m of range, auto-triggers the moment it detects the exposure, and holds captures in a 4 MB onboard buffer — so an image is never lost waiting on the connection.

How is infection control handled on a wireless sensor?

Standard barrier sleeves, exactly like any intraoral sensor. The body is IP67-sealed, so it stands up to wipe-downs between patients, and Zero Profile® holders clip to the back of the sensor without changing your protocol.

Will it actually reduce retakes?

FTG reports up to 40% fewer retakes with DC-Air. With no cable to drag the sensor out of position and 360° distal or mesial placement with Zero Profile® holders, the sensor stays where you put it.

Are the images sharpened or filtered?

No. DC-Air captures receive brightness and contrast adjustment only — never sharpening. FTG’s framing: captured, not synthesized. The brightness and contrast control in our on-page viewer is standard display-side window leveling; the capture itself stays exactly as the sensor recorded it.

What warranty and support come with it?

Every DC-Air includes FTG’s 2-year manufacturer warranty. From Dental TI it also comes with installation, software integration, remote team training (on-site available), and expert support — remote or on-site.

What do replacement holders cost?

Zero Profile® holders are color-coded — Bitewing red, Anterior blue, Posterior yellow, Endodontic clear — and refill 3-packs are available; call for current pricing. The Starter Kit ships with the complete holder kit.


Included with every system

The Dental TI Standard

Equipment is half the purchase. The other half is the team standing behind it.

  1. 01

    Install

    Our own team delivers, mounts, and configures your equipment — nothing is drop-shipped to your doorstep.

  2. 02

    Integrate

    We wire imaging into your practice software and workflow so day one feels like day one hundred.

  3. 03

    Train

    Remote team training on your patients’ schedule, with on-site training available — not a PDF and a phone number.

  4. 04

    Support

    Expert help is a phone call away — remote first for speed, on-site when hardware needs hands. We’ve answered that call since 2003.

Ready to see DC-Air in your operatory?

Book a live demo, or talk to a real imaging expert about whether direct conversion is right for your practice.